CLEAR SAFETY AND SECURITY LAMINATE
Clear safety and security laminate from Protective Glass Solutions is preferred by professional installers for performance, application flexibility and price competitiveness.
- Produced in 4, 7, 8, 12 and 15 mil thickness for versatile resistance to impact, blast and natural disaster
- Holds broken glass together to protect people and property from flying shards
- Multi-layer construction recognized for optical clarity and clean appearance
- Made of top-grade polyester material and fully transparent adhesive
- Manufactured under strict adherence to ISO 9001 quality assurance standards
- Free of distortion and yellowing common to many other safety films available on the market
- Durable scratch-resistant coating for exterior applications
International accreditations: EN 12600, ANSI Z-97.1, BSI 6206, GSA level C & D, CPSC 1201, EN 356, DIN 62290
Click for mechanical, optical and solar properties:
4 MIL CLEAR
MECHANICAL PROPERTIES
| Thickness | 4 mil |
| Tensile Strength at Break | 28,500 PSI |
| Break Strength | 112 lb/inch |
| Elongation at Break | 125% |
| Peel Strength | 7 lb/inch |
OPTICAL AND SOLAR PROPERTIES
| Visible Light Transmitted | 85% |
| Visible Light Reflected | 11% |
| UV Radiation | 90% |
| Total Solar Energy Reflected | 9% |
| Total Solar Energy Transmitted | 77% |
| Total Solar Energy Absorbed | 14% |
| Shading Coefficient | 0.93 |
| Total Solar Energy Rejected | 19% |
All solar performance data is based on laminate being applied to the inside of 1/4-inch clear monolithic annealed glass. All data reported has been measured, calculated and reported in accordance with ASTM, ASHRAE and AIMCAL standards. The data is subject to variations within accepted industry standards.back to top
7 MIL CLEAR
MECHANICAL PROPERTIES
| Thickness | 7 mil |
| Tensile Strength at Break | 26,000 PSI |
| Break Strength | 180lb/inch |
| Elongation at Break | 140% |
| Peel Strength | 7 lb/inch |
OPTICAL AND SOLAR PROPERTIES
| Visible Light Transmitted | 85% |
| Visible Light Reflected | 11% |
| UV Radiation Absorbed | 90% |
| Total Solar Energy Reflected | 9% |
| Total Solar Energy Transmitted | 76% |
| Total Solar Energy Absorbed | 15% |
| Shading Coefficient | 0.91 |
| Total Solar Energy Rejected | 20% |
All solar performance data is based on laminate being applied to the inside of 1/4-inch clear monolithic annealed glass. All data reported has been measured, calculated and reported in accordance with ASTM, ASHRAE and AIMCAL standards. The data is subject to variations within accepted industry standards.back to top
8 MIL CLEAR
MECHANICAL PROPERTIES
| Thickness | 8 mil |
| Tensile Strength at Break | 28,500 PSI |
| Break Strength | 224 lb/inch |
| Elongation at Break | 125% |
| Peel Strength | 7 lb/inch |
OPTICAL AND SOLAR PROPERTIES
| Visible Light Transmitted | 84% |
| Visible Light Reflected | 10% |
| UV Radiation Absorbed | 93% |
| Total Solar Energy Reflected | 10% |
| Total Solar Energy Transmitted | 76% |
| Total Solar Energy Absorbed | 14% |
| Shading Coefficient | 0.92 |
| Total Solar Energy Rejected | 20% |
All solar performance data is based on laminate being applied to the inside of 1/4-inch clear monolithic annealed glass. All data reported has been measured, calculated and reported in accordance with ASTM, ASHRAE and AIMCAL standards. The data is subject to variations within accepted industry standards.back to top
12 MIL CLEAR
MECHANICAL PROPERTIES
| Thickness | 12 mil |
| Tensile Strength at Break | 28,500 PSI |
| Break Strength | 336 lb/inch |
| Elongation at Break | 125% |
| Peel Strength | 7 lb/inch |
OPTICAL AND SOLAR PROPERTIES
| Visible Light Transmitted | 83% |
| Visible Light Reflected | 10% |
| UV Radiation Absorbed | 96% |
| Total Solar Energy Reflected | 11% |
| Total Solar Energy Transmitted | 74% |
| Total Solar Energy Absorbed | 15% |
| Shading Coefficient | 0.9 |
| Total Solar Energy Rejected | 22% |
All solar performance data is based on laminate being applied to the inside of 1/4-inch clear monolithic annealed glass. All data reported has been measured, calculated and reported in accordance with ASTM, ASHRAE and AIMCAL standards. The data is subject to variations within accepted industry standards.back to top
15 MIL CLEAR
MECHANICAL PROPERTIES
| Thickness | 15 mil |
| Tensile Strength at Break | 28,500 PSI |
| Break Strength | 420 lb/inch |
| Elongation at Break | 140% |
| Peel Strength | 7 lb/inch |
OPTICAL AND SOLAR PROPERTIES
| Visible Light Transmitted | 83% |
| Visible Light Reflected | 10% |
| UV Radiation Absorbed | 98% |
| Total Solar Energy Reflected | 11% |
| Total Solar Energy Transmitted | 74% |
| Total Solar Energy Absorbed | 15% |
| Shading Coefficient | 0.9 |
| Total Solar Energy Rejected | 22% |
All solar performance data is based on laminate being applied to the inside of 1/4-inch clear monolithic annealed glass. All data reported has been measured, calculated and reported in accordance with ASTM, ASHRAE and AIMCAL standards. The data is subject to variations within accepted industry standards.back to top